McGinley Services is one of the leading providers of air conditioning repair and air conditioning service in Drexel Hill, PA, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. McGinley Services goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Drexel Hill, PA. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today

Call For Water Leak From Ac. Drain Line Was Clogged. And Vaccumed Air Filters. Showwd Client How. Offer No Guarantee On Drain Remaining Clear Long Term As It Requires Regular Maintenance To Ensure No Issue Recommended Cleaning Air Filter At End Of Every Construction Day. Provided Quote To Remove And Reinstall If Not Going To Be Done By Others To Replace Wall. Ac Running On Departure And Tested Drain Line
Karen , S. Drexel Hill, PA
09-04-2023
HIGH PRESSURE SWITCH - THREADED WITH CORE REPLACE HIGH PRESSURE SWITCH (EXCLUDING REFRIGERANT REMOVAL) WIRING AND VERIFICATION OF PROPER OPERATION
Matt , G. Drexel Hill, PA
09-04-2023
Call For No Ac On 2013 Carrier Ac Was Able To Identify Failed Capacitor. Replaced And Tested Motors Fan Motor Rated .75MAX Running At .70 Witch Is Good. Compressor Rated 12.8MAX Running At 5.8 Witch Is Good. Tested Refrigerant Levels Witch Overall Are Proper However Subcooling (SC) Target Is 10°F System Was Running At 4°F SC Likley High Load In Home. Advise Having System Maintenance And Inspected
Greg , B. Drexel Hill, PA
09-04-2023
Call For Tune Up On 14 Year Old Trane Ac. Client Noted Some Issues Keeping Up On Hot Days. Filter Was Dirty, Washed Trane Clean Air System. Evaporator Coil Is Not Accessible Through Typical Means. Temperature Leaving Ac 55 And Returning 70 Normal Difference Is About 20 And Is Currently 15. Found Outdoor Unit Excessivly Dirty (likley Due To Lack Of Access To Hose Bib) Connected To Clients Washer Line And Washed Outdoor Unit. Compressor Amps 9.2 Rated Max Is 13 Fan Amps 1.2 Rated Max 1.5 Capacitor Rated 45+5 Tested At 43.7+5.4. Contactor Relay Witch Starts Compressor Is Charred And Pitted On Contacts Witch Is Normal Wear And Tear But Should Be Replaced. REFRIGERANT KS FREON AND LEVELS EVEN AFTER CLEANING ARE NOT OKAY SYSTEM HAS A RESTRICTION EFFECTING PERFORMANCE. AC RUNNING ON DEPARTURE Will Email Repair Qoutes
Brady , B. Drexel Hill, PA
09-03-2023
Call For No Ac On 2-3 Year Air Temp Ac Low On Refrigerant Added 1# Of R-410 And Uvdye(no Charge. Should Have Back Out To Check For Leaks And Evidence Of Uv Dye To Be Able To Properly Repair. Ac Running On Departure
Matt , G. Drexel Hill, PA
09-03-2023
Air Conditioner - A/C Service Call / No Cooling
Belinda , B. Drexel Hill, PA
09-02-2023